Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
ACS Appl Mater Interfaces ; 15(22): 27253-27263, 2023 Jun 07.
Artigo em Inglês | MEDLINE | ID: mdl-37216444

RESUMO

Electrocatalytic efficiency and stability have emerged as critical issues in the ethanol oxidation reaction (EOR) of direct ethanol fuel cells. In this paper, Pd/Co1Fe3-LDH/NF as an electrocatalyst for EOR was prepared by a two-step synthetic strategy. Metal-oxygen bonds formed between Pd nanoparticles and Co1Fe3-LDH/NF guaranteed structural stability and adequate surface-active site exposure. More importantly, the charge transfer of the formed Pd-O-Co(Fe) bridge could effectively modulate the electrical structure of hybrids, improving the facilitated absorption of OH- radicals and oxidation of COads. Benefiting from the interfacial interaction, exposed active sites, and structural stability, the observed specific activity for Pd/Co1Fe3-LDH/NF (17.46 mA cm-2) was 97 and 73 times higher than those of commercial Pd/C (20%) (0.18 mA cm-2) and Pt/C (20%) (0.24 mA cm-2), respectively. Besides, the jf/jr ratio representing the resistance to catalyst poisoning was 1.92 in the Pd/Co1Fe3-LDH/NF catalytic system. These results provide insights into optimizing the electronic interaction between metals and the support of electrocatalysts for EOR.

2.
J Fluoresc ; 31(4): 971-979, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-33860872

RESUMO

Zinc ion is closely related to human health. Its content in human body is small, while the effect is large. However, it is not the more the better, must be in a scientific balance. Therefore, it is significant to the rapid detection of Zn2+ in the environment and organism. Herein, a fluorescent probe based on 2-hydroxy-1-naphthalene formaldehyde and furan-2-carbohydrazide was conveniently synthesized via Schiff base reaction. And this probe has been successfully applied to the accurate and quantitative detection of Zn2+ in real samples, showing turn on fluorescence, good selectivity, very low detection limit, real time response and reusability. In addition, this probe has the potential application to trace Zn2+ in living cells with low cytotoxicity.


Assuntos
Fluorescência , Bases de Schiff , Corantes Fluorescentes
3.
Luminescence ; 36(4): 923-927, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-33458934

RESUMO

Hydrosulphite (HSO3 - ), as a common and important chemical reagent, is widely used in everyday life, however excessive use and abuse of HSO3 - can cause potential harmful effects on the environment and in biological health. In this paper, we describe the design and preparation of a colorimetric and ratiometric fluorescence probe for the visual detection of HSO3 - (excitation wavelengths were, respectively, 336 nm and 520 nm). This method showed some advantages including simple preparation, high selectivity, fast response, and significant colour and fluorescence ratio (F450 /F594 ) changes in the presence of HSO3 - . In addition, this probe was used successfully for the detection of HSO3 - in real water samples and showed a good recovery rate range.


Assuntos
Colorimetria , Corantes Fluorescentes , Água
4.
Spectrochim Acta A Mol Biomol Spectrosc ; 71(4): 1246-9, 2008 Dec 15.
Artigo em Inglês | MEDLINE | ID: mdl-18450504

RESUMO

A novel method for the determination of proteins by using tetracarboxy manganese(II) phthalocyanine (MnC4Pc) as a resonance light scattering (RLS) probe has been developed. At pH 3.0 Britton-Robinson (B-R) buffer solution, the RLS intensity of MnC4Pc at 385 nm is greatly enhanced in the presence of proteins. The effects of pH, reaction time, concentration of MnC4Pc and interfering substances on the enhanced RLS intensity are investigated, respectively. Under optimal conditions, the linear ranges of the calibration curves are 0-2.00 microg mL(-1) for bovine serum albumin (BSA) and human serum albumin (HSA), 0.0-1.75 microg mL(-1) for human-IgG and ovalbumin, with a detection limit of 16.37 ng mL(-1) BSA, 17.62 ng mL(-1) HSA, 19.41 ng mL(-1) human-IgG and 20.72 ng mL(-1) ovalbumin. The method has been applied to the determination of total proteins in human serum samples collected from a hospital and the results are in good agreement with those reported by the hospital.


Assuntos
Indóis/química , Manganês/química , Compostos Organometálicos/química , Proteínas/análise , Animais , Soluções Tampão , Calibragem , Bovinos , Humanos , Concentração de Íons de Hidrogênio , Imunoglobulina G/química , Indóis/farmacologia , Isoindóis , Luz , Compostos Organometálicos/farmacologia , Ovalbumina/química , Proteínas/química , Espalhamento de Radiação , Soroalbumina Bovina/química , Espectrometria de Fluorescência/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...